- 1)
- Please note: can be used only for installation in vertically installed pipelines between two flanges (e.g. between duckfoot bend and hydrant).
- 2)
- Please note: can be used only for installation in horizontally installed pipelines between two flanges.
- 3)
- Only between PN 10
859-00
Wafer type tee piece with ZAK® outlets
| Material: |
Body: GJS-400, Hawle epoxy powder coated O-ring: EPDM acc. to KTW-BWGL for water |
|---|---|
| Max. operating Pressure: | See table |
| Medium | Water |
Wafer type tee piece with ZAK® outlets and integral flange gaskets (O-rings) for the quick and easy installation between two flanges.
Via the two ZAK® outlets a restraint integration of valves and fittings with ZAK® spigot end is possible.
|
Order Nr.
|
*) |
DN |
Operating pressure max. |
L |
B |
B1 |
D � |
Outlet O |
Medium | Weight | Specification | Basket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
8590500460
|
2) | 50 | 16 bar | 70 mm | 228 mm | 98 mm | 2x ZAK 46 | 3,80 kg | ||||
|
8590650460
|
2) | 65 | 16 bar | 70 mm | 250 mm | 118 mm | 2x ZAK 46 | 4,74 kg | ||||
|
8590800461
|
1) | 80 | 16 bar | 70 mm | 260 mm | 130 mm | 2x ZAK 46 | 3,56 kg | ||||
|
8591000460
|
2) | 100 | 16 bar | 70 mm | 300 mm | 150 mm | 2x ZAK 46 | 3,41 kg | ||||
|
8591000463
|
1) | 100 | 16 bar | 70 mm | 300 mm | 150 mm | 4 x ZAK 46 | 6,70 kg | ||||
|
8591250460
|
2) | 125 | 16 bar | 70 mm | 318 mm | 185 mm | 2x ZAK 46 | 8,28 kg | ||||
|
8591500460
|
2) | 150 | 16 bar | 70 mm | 340 mm | 215 mm | 2x ZAK 46 | 5,34 kg | ||||
|
8591500463
|
1) | 150 | 16 bar | 70 mm | 340 mm | 215 mm | 4 x ZAK 46 | 10,98 kg | ||||
|
8591500696
|
1) 2) | 150 | 16 bar | 90 mm | 337 mm | 215 mm | 1 x ZAK 69 | 13,70 kg | ||||
|
8592000460
|
2) | 200 | 16 bar | 70 mm | 360 mm | 265 mm | 2x ZAK 46 | 6,83 kg | ||||
|
8592000463
|
1) | 200 | 16 bar | 70 mm | 360 mm | 265 mm | 4 x ZAK 46 | 13,63 kg | ||||
|
8592000696
|
1) 2) 3) | 200 | 10 bar | 90 mm | 387 mm | 265 mm | 1 x ZAK 69 | 17,12 kg | ||||
|
8592500460
|
2) | 250 | 16 bar | 70 mm | 420 mm | 320 mm | 2x ZAK 46 | 10,71 kg | ||||
|
8593000460
|
2) | 300 | 16 bar | 70 mm | 470 mm | 370 mm | 2x ZAK 46 | 12,45 kg | ||||
|
8594000460
|
2) | 400 | 16 bar | 70 mm | 570 mm | 480 mm | 2x ZAK 46 | 16,25 kg |
-
The installation instructions must be observed so that the assembled isolation valves are in a vertical installation.
|
Further information
|
|---|
| General instruction for Fittings |
|
Operating instructions
|
|---|
| Operating and maintenance instructions - Hawle ZAK®-System |
| Operating and maintenance instructions - Wafer type tee piece with ZAK® outlets |
|
Brochures
|
|---|
| Brochure ZAK 69 |
|
Article Nr.
|
Product description |
|---|---|
| 249-00 | ZAK® plug |
| 616-00 | Push-fit fitting with ZAK® spigot end |
| 616-01 | Push-fit fitting with detachable taper ring and ZAK® spigot end |
| 618-00 | ZAK® PE fusion end |